Sturtevant Richmont Torque Measurement Systems Worldwide! Call: 1 847/455-8677
US only toll-free: 1 800/877-1347
customerservice@srtorque.com

Digital Torque Testers and Torque Tester Calibration Equipment

Torque tools require calibration and recalibration at intervals that assure the tools remain accurate while keeping the ownership cost of the tools at minimum. The selection of the best strategy for assuring accuracy must be followed by selection of the appropriate tester(s) and support equipment to achieve the goals.

We have two papers to assist you in strategy determination and tester selection. We strongly urge you to read them and use the information to assist in determining the best equipment for your operation. These papers are:

Data-Driven Torque Wrench Calibration Frequency
Technical and Operational Considerations in Torque Tester Selection


Single-Transducer Static torque testers

Torq-Tronics 2®

  • Greater accuracy and durability with simplicity and ease of operation
  • Floating decimal point, 6 digit display is easy to read
  • Accurate to +/- .5% (indicated value) from 10% to 100%
  • Over capacity alert and tracking
  • Built for accuracy and durability, meets or exceeds ASME B107.300, ASME B107.4M, ISO 5993, ISO 1773, 1774-2

 

VeriTorq®

  • +/- 1% I. V. Accuracy
  • Three modes of operation - Track, Peak and Clicker
  • Four buttons do everything
  • Excellent for interim checks.
  • Suitable for all manual torque tools of +/- 4% I.V. Accuracy or less.
  • Includes FREE certificate of calibration from our ISO/IEC 17025 Accredited Calibration Laboratory!
Static torque transducer compatibility chart

All of the torque transducers listed here are designed to work with both System 4 and System 5 Digital Torque Testers. Each has differing mounting options and/or mechanical loader compatibility. This chart will help you select the best transducer models for your application.

* Must be within torque limits of loader. Not for transducers of greater than 250 ft. lb. capacity.
** Requires optional bracket.

Transducer ML 250 Quad Plate ML 1000 ML 2000 Vertical Mount Horizontal Mount
TT
Series
Yes Yes*     Yes Yes**
STT-P
Series
Yes* Yes*     Yes Yes**
STT-QC
Series
    Yes Yes    
TT-MLQC Series     Yes Yes    
STT-L
Series
        Yes Yes

 

Tester Related Information

Torque Tester Calibration Equipment

Torque tester calibration is identical to torque tool calibration in its’ necessity, but of significantly greater technical difficulty in obtaining the required accuracy.  Here is a short list of impacting factors:

  • The rigidity and stability of the mounting base.
  • The distance from the center of the tester drive to the center of the cable of the weights.
  • Accuracy of the weights being used.
  • The gravitational variation where the calibration testing is performed is important.
  • Room temperature and humidity.

Go to our Torque Tester Calibration Equipment page to see the range of S/R offerings, and how we can help you obtain the accuracy critical to success.